Techdee

Introduction to Steam Traps in Piping Systems

A Piping system is an arrangement of pipes, valves, and other components used to transport heat energy in the form of steam. Efficiency is vital with any piping system, and steam traps are the most critical components for maintaining efficiency.

Steam traps are designed to monitor the flow of steam in a piping system and remove condensate, noncondensable gasses, and air from that flow to keep the system running smoothly.

Steam traps are typically installed in commercial and industrial facilities, such as HVAC systems (heating, ventilation, and air conditioning systems), power plants, manufacturing plants, and hospitals.

In this blog post, we will introduce steam traps and discuss the available types. We will also talk about how steam traps can help improve the performance of your piping system.

The Steam Traps in Piping Systems

Steam traps are valves used to control steam flow in a piping system. They work by allowing condensed vapor (condensate) and non-condensable gasses to pass through while trapping the steam inside.

This helps maintain the desired pressure levels and temperature and prevents air or water from entering the system. Steam traps feature a diaphragm that senses the pressure of the steam and allow it to escape when necessary.

Additionally, these valves may be used to prevent backflow and regulate the temperature within the system.

Different Types of Steam Traps

Steam traps are life savers in the industry as they help to remove condensation from process lines while preventing live steam loss. There are three main types of steam traps- mechanical, thermostatic, and thermodynamic.

Mechanical Steam Trap

A mechanical steam trap is a valve that automatically drains the condensate (water) from a steam system. It is typically used in high-pressure systems, where the condensate can be hot and corrosive. The trap consists of a body, float, and valve.

The valve is opened and closed by the weight of the float, which rises and falls with the level of condensate in the body. As the float rises, the valve opens, allowing the condensate to drain. When the condensate level drops, the float falls and closes the valve.

This prevents steam from escaping from the system. Mechanical steam traps are reliable and require little maintenance, making them a popular choice for many industrial applications.

Thermostatic Steam Trap

Thermostatic traps use a difference in temperature to operate. The decrease in the internal pressure of the trap body due to condensate and the size of the orifice helps to control the condensate flow and prevent live steam from escaping.

When the condensate temperature drops below the set point, the trap opens and allows the condensate to drain. As the condensate level decreases, the trap closes again to prevent live steam from escaping. Thermostatic steam traps are very reliable and can be used in various applications.

Thermodynamics Steam Trap

Thermodynamic steam traps use a combination of temperature and pressure to operate. They are sensitive to small changes in pressure and temperature, allowing for better control than other types of steam traps.

As the condensate moves through the trap, the difference in temperature causes the internal pressure to drop, which in turn causes the disc valve to open and close. This allows the condensate to drain away while the steam passes through.

When the pressure in the trap is higher than that of the system, it opens and allows condensation to escape. As the condensate level drops and the pressure decreases, the valve closes again, preventing steam from escaping.

How Steam Traps Can Help Improve Performance

Steam traps can help improve the performance of piping systems in a few key ways.

Maintain Desired Pressure

Steam traps are essential components of any piping system, as they help maintain the desired pressure levels while preventing live steam from escaping. This helps improve the system’s overall performance by ensuring it runs efficiently and effectively.

Control Air or Water Entering the System

Steam traps also help to prevent air or water from entering the system. This helps keep the steam at the desired pressure and temperature, thus improving efficiency, safety, and reliability. 

Additionally, preventing air or water from entering the system helps protect against corrosion that can occur over time.

Regulate Temperature within the System

Steam traps regulate the temperature within the system, as they can open and close when necessary to release condensate or air. This helps ensure that the steam is at a consistent temperature throughout the system, which helps prevent clogging in the pipes or other components.

Reduce Maintenance Costs

The use of steam traps also reduces maintenance costs. The traps reduce wear and tear on pipes and other components by preventing live steam from escaping. This helps extend your system’s life and can significantly reduce maintenance costs over time.

Maintenance and Care for Steam Traps

Regular maintenance and care of steam traps are essential to ensure they operate correctly and efficiently. Here are some practices to ensure that your system is performing optimally:

Regular Monitoring and Inspection of the Trap

Regularly check for trap leakage, which various factors, including corrosion and mineral deposits, can cause. Also, inspect the trap body for any signs of wear or damage. If the trap leaks, it should be replaced as soon as possible to avoid further problems with efficiency.

Monitoring can be done with a steam trap monitoring wireless sensor by Pulse Industrial; this will help to reduce downtime and improve reliability.

Cleaning the Trap to Improve Performance

Regularly clear debris from around the trap body, as this can cause blockages and reduce performance. In addition, if the trap is equipped with a strainer or filter, it should be cleaned to remove any build-up of material blocking airflow.

Replacement of Worn Traps

If your steam traps show wear and tear, they should be replaced to ensure the system runs optimally. Steam traps can be expensive, so it is crucial to ensure they are inspected and maintained regularly to prevent any costly repairs or replacements in the future.

Regular Maintenance of Piping Systems

In addition to caring for your steam traps, regular maintenance of all components in a piping system should be carried out. This includes cleaning, testing, and checking for any signs of damage or corrosion that can affect the system’s efficiency.

By practicing proper maintenance and care of your steam trap system, you can ensure optimum performance and reduce costly repairs in the future.

Wrapping Up

A steam trap is a critical component of any piping system which functions by removing condensate from steam lines. It helps maintain the desired pressure, control air or water entering the system, regulate the temperature, and reduce maintenance costs.

The type of steam trap used depends on your specific needs, but whatever you choose should be reliable and require minimal maintenance. Using a steam trap in your piping system can ensure that your system is working at its peak efficiency and that it is safe for everyone involved.